OPERATING INSTRUCTION MANUAL
MODEL 2200R
ORP ANALYZER
REV. 10
Water Analytics, Inc.
100 School Street
Andover, MA 01810
Tel: (978) 749-9949
(888) 749-9099
Fax: (978) 749-9961
www.WaterAnalytics.net
Zobrazit stránku 0
1 2 3 4 5 6 ... 29 30

Shrnutí obsahu

Strany 1 - REV. 10

OPERATING INSTRUCTION MANUAL MODEL 2200R ORP ANALYZER REV. 10 Water Analytics, Inc. 100 School Street Andover, MA 01810 Tel: (978)

Strany 2 - TABLE OF CONTENTS

Model 2200R Page 8 4.0 Description of Functions 4.1 Overview 4.1.1 The Model 2200R is a

Strany 3 - INSTRUCTION MANUAL

Model 2200R Page 9 4.2 Calibration 4.2.1 All ORP systems need to be calibrated when first placed in service and

Strany 4 - 2.0 SPECIFICATIONS

Model 2200R Page 10 4.5 Analog Outputs 4.5.1 The analog output signals consists of a non-isolated 0-1 mA, 0-5 Vdc, and isolat

Strany 5 - 3.0 INSTALLATION

Model 2200R Page 11 4.6 Operation Menu 4.6.1 The operation menu allows the user to recall and to adjust the parameters, required

Strany 6

Model 2200R Page 12 4.7 DIP Switches 4.7.1 The controls which are frequently used in the normal operation of the in

Strany 7

Model 2200R Page 13 4.9 Parameter and Operation Checking 4.9.1 The instrument continuously checks all parameters in i

Strany 8

Model 2200R Page 14 5.0 START-UP AND OPERATION 5.1 Password 5.1.1 To enter the menu pr

Strany 9

Model 2200R Page 15 5.4 Analog Output Range Expand 5.4.1 To increase the resolution of the analog outputs, the rang

Strany 10

Model 2200R Page 16 a) Enter the menu by pressing CALL, proceed by pressing CALL until the RELAY A DEADBAND LED is illuminated. Now use the arr

Strany 11

Model 2200R Page 17 5.10 Cycle Feature for Relays A and B 5.10.1 The 2200R has a cycling feature for the control relays. This feature if enab

Strany 12

TABLE OF CONTENTS SECTION DESCRIPTION PAGE 1 GENERAL INFORMATION 1 2 SPECIFICATIONS 2 3 INSTALLATION 3 4 DESCRIPTION

Strany 13

Model 2200R Page 18 5.12 Alarm Low 5.12.1 To set the ALARM LOW proceed as follows: a) Press CALL to enter the me

Strany 14

Model 2200R Page 19 5.15 Status 5.15.1 The 2200R continuously checks the integrity of all stored data and monitors the con

Strany 15

Model 2200R Page 20 6.0 OPERATING HINTS 6.1 Probe Care 6.1.1 Keep the pro

Strany 16

Model 2200R Page 21 7.0 UTILITY MENU 7.1 Utility Menu Functions 7.1.1 The Utility

Strany 17

Model 2200R Page 22 7.4 Adjust 0-1 mA / 0-5 Vdc Output 7.6.1 It may be desirable to fine tune the 0-1 mA / 0-5

Strany 18

Model 2200R Page 23 8.0 DIAGNOSTICS 8.1 Description 8.1.1 The 2200R has diagnostic features which alerts the operator t

Strany 19

Model 2200R Page 24 9.0 TROUBLESHOOTING AND SERVICE 9.1 Calibration / Display Problem 9.1.1 If the problem is one of inability t

Strany 20

Model 2200R Page 25 b) To check the temperature channel move the slide switch S41 from position “ON LINE” to position TEST. Go to the TEM

Strany 21

Model 2200R Page 26 • Alarm Relay – See Sections 5.10 and 5.11 • The cycling parameters if so equipped – See Section 5.14 f) After all th

Strany 22 -

Model 2200R Page 27 9.7 Parts and Accessories 9.7.1 The major parts are listed below. When ordering parts please

Strany 23

Model 2200R Page 1 MODEL 2200R ORP CONTROLLER INSTRUCTION MANUAL 1.0 GENERAL INFORMATION The

Strany 24

Model 2200R Page 28 STATEMENTS OF CONFORMITY FROM THE MANUFACTURER U.S.A. WARNING: This equipment gener

Strany 25 - 8.0 DIAGNOSTICS

Model 2200R Page 2 2.0 SPECIFICATIONS DISPLAY: 4 x 7 segment ½” LED Display MEASURING RANGES: ORP: 0 to 1000mV o

Strany 26

Model 2200R Page 3 3.0 INSTALLATION 3.1 Location 3.1.1 Install the instrument within 3000 feet

Strany 27

Model 2200R Page 4 3.4 Electrical Connections The 2200P is available in 3 different power options, 12

Strany 28

Model 2200R Page 5 24Vdc 3.4.3 To access the terminal strips open the door of the instrument and then unscrew the captive retaining screw ne

Strany 29

Model 2200R Page 6 3.5 Sensor Connections 3.5.1 Jumpers J42 are used to select which type of probe is being used. If a

Strany 30

Model 2200R Page 7 3.6 Sensor Connections; Combination Probe (P500 Series) Without Temperature Compensation 3.6.1 a) Both J42 jumpe